Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
 
FIND ARTICLES

jssm
jssm

Journal of Sports Science and Medicine
ISSN: 1303 - 2968
       SCImago 2016     SJR: 0.981   Cites per Doc. 2-Year: 2.04    3-Year: 2.17
JCReports 2016
    IF 2-Year: 1.797    3-Year: 1.970    5-Year: 2.061    Average Citations PI: 7.7
 
©Journal of Sports Science and Medicine (2015) 14, 62 - 68
Research article
A Self-Paced Intermittent Protocol on a Non-Motorised Treadmill: A Reliable Alternative to Assessing Team-Sport Running Performance
Paul J. Tofari1,, Blake D. McLean1,2, Justin Kemp1, Stuart Cormack1

1 School of Exercise Science, Australian Catholic University, Melbourne, Australia
2 Sport Science Department, Collingwood Football Club, Melbourne, Australia

Paul J. Tofari
✉ Australian Catholic University, Locked Bag 4115, Fitzroy, MDC, Victoria, Australia, 3165
Email: Ptofari@gmail.com

Received:
01-09-2014 -- Accepted: 14-10-2014 --
Published (online): 01-03-2015

ABSTRACT

This study assessed the reliability of a ‘self-paced’ 30-min, team-sport running protocol on a Woodway Curve 3.0 non-motorised treadmill (NMT). Ten male team-sport athletes (20.3 ± 1.2 y, 74.4 ± 9.7 kg, VO2peak 57.1 ± 4.5 ml·kg-1·min-1) attended five sessions (VO2peak testing + familiarisation; four reliability trials). The 30-min protocol consisted of three identical 10-min activity blocks, with visual and audible commands directing locomotor activity; however, actual speeds were self-selected by participants. Reliability of variables was estimated using typical error ± 90% confidence limits expressed as a percentage [coefficient of variation (CV)] and intraclass correlation coefficient. The smallest worthwhile change (SWC) was calculated as 0.2 × between participant standard deviation. Peak/mean speed and distance variables assessed across the 30-min protocol exhibited a CV < 5%, and < 6% for each 10-min activity block. All power variables exhibited a CV < 7.5%, except walking (CV 8.3-10.1%). The most reliable variables were maximum and mean sprint speed (CV < 2%). All variables produced a CV% greater than the SWC. A self-paced, team-sport running protocol performed on a NMT produces reliable speed/distance and power data. Importantly, a single familiarisation session allowed for adequate test-retest reliability. The self-paced design provides an ecologically-valid alternative to externally-paced team-sport running simulations.

Key words: Exercise test, athletic performance, running, reproducibility of results
Key Points
  • Self-paced team-sport running protocols on a curved NMT that closely match the locomotor demands of competition deliver reliable test-retest measures of speed, distance and power.
  • Such protocols may be sensitive to changes in running profile following an intervention that may not be detectable during externally-paced protocols.
  • One familiarisation session is adequate to ensure test-retest reliability.
  •  


      

    Article Tools
    How to Cite
    Citations in ScholarGoogle 
    Email link to this article
    Paul J. Tofari, Blake D. McLean, Justin Kemp, Stuart Cormack, (2015) A Self-Paced Intermittent Protocol on a Non-Motorised Treadmill: A Reliable Alternative to Assessing Team-Sport Running Performance. Journal of Sports Science and Medicine (14), 62 - 68.

    Your name:

    *

    Your E-mail:

    *
    Recipient's E-mail: *
    *Required Field
    Statistics
    Article views from publication date
    Abstract :4760
    Full-text :4165
    Pdf :489
    Total :9414
    New content alert
     
    JSSM | Copyright 2001-2017 | All rights reserved. | LEGAL NOTICES | Publisher
    It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind
    of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.