Table 2. Moderators of handgrip strength reproducibility. Longitudinal Stability (T1, baseline; T2, second year; T3, third year; T4, fourth year).
Absolute Error (kg) %CV MD (kg)
1-year interval T1 vs T2 3.00 (95% CI: 2.92 – 3.09)* 5.0 (95% CI: 4.9, 5.2)* 7.7
T2 vs T3 3.09 (95% CI: 3.01-3.09)* 5.1 (95% CI: 5.0, 5.3)* 8.1
T3 vs T4 3.04 (95% CI: 2.96-3.13)* 5.1 (95% CI: 4.9, 5.2)* 7.9
2-year interval T1 vs T3 3.25 (95% CI: 3.16 – 3.34) 5.4 (95% CI: 5.3, 5.6) 8.3
T2 vs T4 3.21 (95% CI: 3.12-3.30) 5.4 (95% CI: 5.2, 5.5) 8.3
3-year interval T1 vs T4 3.29 (95% CI: 3.20 – 3.38) 5.5 (95% CI: 5.4, 5.7) 8.3
Sex Male 3.5 (95% CI: 3.4, 3.5)* 6.0 (95% CI: 5.9 – 6.1)* 8.9
Female 2.3 (95% CI: 2.2, 2.4) 6.3 (95% CI: 6.1 – 6.5) 5.9
Handgrip device Digital 2.9 (95% CI: 2.9, 3.0)* 5.9 (95% CI: 5.8 – 6.0)* 7.8
Analog 3.8 (95% CI: 3.7, 4.0) 6.5 (95% CI: 6.3 – 6.7) 9.3
* indicates statistical significance; CV, coefficient of variation; MD, minimal difference.