Research article - (2026)25, 866 - 874
DOI:
https://doi.org/10.52082/jssm.2026.866
A Progressive 20m Shuttle Run Test to Estimate Maximum Oxygen Consumption in Ten Different Sports
Hyeong-Tae Kwon1, Daeho Kim2,
1Center for Sport Science in Incheon, Incheon, Korea
2Department of Sports Rehabilitation Medicine, Kyungil University, Gyeongsan, Korea

Daeho Kim
✉ Department of Sports Rehabilitation Medicine Kyungil University 50 Gamasilgil, Hayangeup, Gyeongsan, Korea, 38428
Email: daehokim@kiu.kr
Received: 07-07-2026 -- Accepted: 07-09-2026
Published (online): 01-12-2026
Narrated in English

ABSTRACT

Cardiorespiratory fitness is a fundamental determinant of both health outcomes and athletic performance, and is most objectively quantified through maximal oxygen uptake (VO2max). Although laboratory-based graded exercise testing (GXT) with expired gas analysis remains the criterion method for VO2max assessment, its practical application is limited by cost, equipment requirements, and the time needed to evaluate large groups. To overcome these limitations, the 20-meter multistage shuttle run test (20m-MST) has emerged as one of the most widely adopted field-based tools due to its simplicity and capacity for simultaneous group assessment. However, existing VO2max prediction models based on the 20m-MST have largely been derived from small, sport-specific samples, limiting their generalizability to broader elite athletic populations. Therefore, the purpose of this study was to verify the validity of the 20m-MST and to develop a precise, field-applicable VO2max prediction model for elite athletes across a wide range of ages, sexes, and sports disciplines. A total of 564 elite athletes (males = 336, females = 228; age range: 13-35 years) were recruited from 10 sports disciplines. Each participant completed both the 20m-MST and a laboratory-based maximal GXT with concurrent expired gas analysis, with a minimum interval of one week maintained between the two assessments. The GXT was conducted using the KISS Protocol, with VO2max determined when at least two of five established physiological criteria were satisfied. Multiple regression analysis was conducted to develop a VO2max prediction equation using shuttle run lap count, age, sex, and body weight as predictor variables, and both the intraclass correlation coefficient (ICC) and Bland-Altman analysis were employed to evaluate the reliability and limits of agreement between predicted and measured values. Correlation analysis revealed a statistically significant positive correlation between VO2max and 20m-MST lap count across all subgroups (r = 0.700, p < 0.001). The regression model yielded a multiple correlation coefficient of r = 0.833, an explanatory power (R2) of 69.4%, and a standard error of estimate of 3.31 mL/kg/min. Validation demonstrated an ICC of r = 0.901, reflecting excellent agreement, with a mean difference of -0.031 ± 3.30 mL/kg/min and Bland-Altman limits of agreement of -0.17 ± 6.13% (95% CI: -0.30 to 0.24). The 20m-MST involves progressively increasing speed with repeated directional changes, indicating that both aerobic and anaerobic energy systems contribute to performance, and shuttle run results should therefore be interpreted as a composite indicator reflecting VO2max alongside agility and anaerobic capacity. The inclusion of age, sex, and body weight as predictor variables allows for VO2max estimation across both sexes and a broad age range within a single unified equation, representing a substantial improvement over previously reported models derived from limited samples. The developed prediction model demonstrated excellent validity and reliability, providing a practical and accurate tool for the assessment of cardiorespiratory endurance in elite athletes. Future research should consider refinements to the shuttle run protocol and the incorporation of correction factors for anaerobic energy contributions to further enhance the precision of VO2max estimation in diverse athletic populations.

Key words: VOmax, shuttle run test, athletes, estimation equation

Key Points
  • The model demonstrated a high correlation between measured and predicted VOmax values (r = .833) with acceptable prediction accuracy (SEE = 3.31 mL/kg/min).
  • Validation of the model further confirmed a strong criterion validity (r = .901) and an acceptable margin of error (-0.031 ± 3.30 mL/kg/min) between directly measured and estimated values.
  • These findings suggest that the developed model constitutes a practical and valid assessment tool applicable to a broad athletic population ranging from middle school to adult-level athletes.








Back
|
Full Text
|
PDF
|
Share