| Research article - (2026)25, 934 - 949 DOI: https://doi.org/10.52082/jssm.2026.934 |
| Effects of Attachment Type on Phase-Specific Surface Electromyographic Amplitude During The Front Lat Pulldown: A Randomized Crossover Study |
Di Lu1,3,†, Cheng Chen2,3,†, Tianyuan He2,3,†, Jiaxin He2,3, Jian Sun2,3, Duanying Li2,3, |
| Key words: Surface electromyography, resistance exercise, exercise technique, sEMG amplitude, strength training |
| Key Points |
|
|
|
| Participants |
An a priori sample-size calculation based on previous between-condition differences in lat pulldown sEMG amplitude indicated that at least 14 participants were required (alpha = 0.05, power = 0.80, Cohen's f = 0.35) (Signorile et al., The study was approved by the local institutional ethics committee (approval no. 2025LCLL-120) and prospectively registered in the Chinese Clinical Trial Registry (ChiCTR2500110939). All procedures were performed in accordance with the Declaration of Helsinki, and all participants provided written informed consent before participation. Written informed consent for publication of identifiable photographs was also obtained from the participant/model shown in |
| Experimental approach to the problem |
A randomized crossover design was used to compare normalized sEMG amplitude across attachment conditions and cadence-defined lifting and lowering analytical intervals during the front lat pulldown. Participants completed the exercise with four attachments: straight bar, wide V-shaped handle, cambered bar, and rope. Condition order for the experimental sessions was randomized using a Williams balanced Latin-square scheme. Grip width was standardized to 1.5 times biacromial width, consistent with previous grip-width work in the lat pulldown (Lusk et al., |
| Procedures Familiarization |
During the three familiarization sessions, participants completed anthropometric assessment, practiced the front lat pulldown with each attachment, and became familiar with the standardized cadence and technique criteria. Electrode sites were also identified and checked to improve placement consistency across later sessions. Attachment configurations are shown in Each repetition began from a seated start position with a pronated grip, full elbow extension with the arms extended overhead, the thighs fixed beneath the leg pad, and the pelvis stabilized on the seat. Participants maintained a slight torso recline throughout the repetition to avoid bar-head contact while minimizing trunk motion. The attachment was pulled in front of the body toward the upper- to mid-chest during the intended lifting portion, with the elbows drawn downward without excessive backward displacement, and returned under control to the starting position during the intended lowering portion. A metronome prescribed a nominal 2-second lifting and 2-second lowering cadence. Acceptable technique required full elbow extension at the start and end of the repetition, an upper- to mid-chest endpoint, symmetrical hand placement, stable pelvis and thigh contact with the pad, and no progressive trunk layback. A repetition was repeated or excluded when the participant clearly failed to follow the prescribed metronome rhythm, failed to reach the standardized endpoint, failed to return to full elbow extension, showed visible hand asymmetry or grip slippage, or showed excessive trunk movement. Technique and cadence compliance were screened during testing and later reviewed offline from the movement trajectory; sEMG recordings were reviewed separately for signal quality. The standardized front lat pulldown technique required during testing is illustrated in |
| Attachment-specific 1RM testing |
One-repetition maximum (1RM) testing was performed separately for the straight bar, wide V-shaped handle, cambered bar, and rope. For each condition, participants completed a standardized warm-up followed by progressively heavier single-repetition attempts. Load was increased until the participant could no longer complete the repetition through the standardized range of motion without technique deviation. Three to five minutes of rest were provided between maximal attempts, and the heaviest successfully completed load was recorded as the condition-specific 1RM. Each attachment-specific 1RM was assessed in its own laboratory session. At least 48 hours separated each 1RM session from the corresponding experimental session. |
| Experimental sessions |
At each experimental session, participants first performed maximal voluntary isometric contraction (MVIC) testing for the monitored muscles. The MVICs were used to provide the normalization reference for the sEMG data. Three 5-second trials were completed per muscle with 3 minutes of rest between trials, and muscle order was randomized across participants to reduce order and fatigue effects (Konrad, Participants performed five repetitions at 70% of attachment-specific 1RM during each experimental session. Repetitions were first screened for technique, cadence compliance, and sEMG signal quality, with emphasis placed on technically consistent early-set observations. When an earlier repetition was unusable because of technique or cadence deviation, electrode detachment, abnormal signal noise, or marked movement artifact, the next eligible repetition was used. The retained valid repetitions from this screening were used to define the participant-specific right-latissimus-dorsi activity-onset reference described below. After EMG-defined activity onset had been determined, analytical-window availability was assessed; an observation was excluded at the segmentation stage if sufficient signal duration was not available for the predefined analytical windows. Exclusion decisions were made during data collection when clear deviations were visible and were confirmed during offline signal-quality and analytical-window checks. Because attachment type was visually apparent, assessors were not blinded to attachment condition during technique screening. Only observations passing the signal-quality and analytical-window availability checks entered the statistical models. The retained-repetition distribution is reported in |
| Surface electromyography and analytical-interval definition |
Surface electromyography (sEMG) was recorded from the right latissimus dorsi, middle trapezius, posterior deltoid, biceps brachii, and triceps brachii using wireless bipolar bar electrodes (Trigno Avanti, Delsys, USA; interelectrode distance 10 mm). Signals were acquired using EMGworks Acquisition v4.8.0 (Delsys, USA). Right-side recording was selected to standardize setup time and electrode placement across conditions; it was not intended to assume bilateral equivalence. Hand dominance was not used as an eligibility criterion or entered into the analysis; therefore, potential dominance-related or side-to-side differences could not be evaluated. Electrode placement used Barbero et al.,( Skin was prepared by shaving when necessary, gentle abrasion, and cleaning with alcohol before electrode placement. For the latissimus dorsi, electrodes were placed over the muscle belly inferior to the scapula and lateral to the thoracolumbar region, aligned with the local fiber direction. For the middle trapezius, electrodes were placed over the muscle belly between the medial scapular border and thoracic spinous processes; because local middle-trapezius fibers run primarily mediolaterally in the selected region, the electrode bars were oriented transversely relative to the spine and parallel to the local fiber direction. For the posterior deltoid, electrodes were placed over the posterior shoulder muscle belly inferior to the posterior acromion and aligned toward the deltoid tuberosity. For the biceps brachii, electrodes were placed over the anterior upper-arm muscle belly and aligned with the longitudinal fiber direction. For the triceps brachii, electrodes were placed over the posterior upper-arm muscle belly and aligned with the longitudinal fiber direction. The same assessor located electrode sites across sessions using anatomical landmarks; exact between-session replication cannot be guaranteed because electrodes were removed after each session. Signals were sampled at 2048 Hz. Raw sEMG signals were band-pass filtered (20-400 Hz), full-wave rectified, and converted to root mean square (RMS) amplitude (Konrad, Three-dimensional kinematic data were collected using a Qualisys motion-capture system (Qualisys AB, Gothenburg, Sweden) consisting of 10 Arqus cameras and one synchronization unit, at a sampling frequency of 200 Hz. Ground reaction force data were collected using Bertec three-dimensional force plates (Bertec Corporation, Columbus, OH, USA) at 1000 Hz. Before each experimental session, the capture volume was calibrated according to the manufacturer's procedures, and marker trajectories were checked during acquisition and offline processing to ensure adequate reconstruction quality. Reflective markers were placed according to the upper-body component of the official H-Motion full-body marker model. This marker set included anatomical landmarks required to reconstruct the trunk, shoulder girdle, upper arm, forearm, and hand segments. In the present analysis, the motion-capture data were used to independently characterize movement execution, including range of motion, cadence, endpoint criteria, and velocity-defined active-motion duration. Because the motion-capture and sEMG systems did not share a common time base, kinematic events were not used to assign individual sEMG samples to mechanical phases. Raw kinematic and kinetic data were processed in Visual3D x64 Professional v2023.06.7 (C-Motion, Inc., Germantown, MD, USA). Marker trajectories and model-derived variables used for kinematic verification were low-pass filtered using the Visual3D low-pass filtering function with a cut-off frequency of 15 Hz. A velocity-based kinematic event algorithm applied to the reconstructed upper-body marker trajectories was used to derive pull and return active-motion durations. These values represent the velocity-defined active-motion portions associated with movement toward and away from the chest; they are distinct from, and were not intended to reproduce, the complete nominal 2.0-second metronome-prescribed lifting or lowering intervals. Participant-by-attachment mean active-motion durations were used for independent cadence characterization and as covariates in the duration-adjusted sensitivity analysis. They were not used to time-register the sEMG record or to assign mechanical events to individual sEMG samples. Before each trial, the motion-capture system was started first, followed by the sEMG system. Once both systems were recording, a standardized verbal command was given for the participant to begin the front lat pulldown. For sEMG analytical-window definition, repetition-activity onset was operationally identified from the right latissimus dorsi (LD) sEMG channel. After the 20-400 Hz band-pass filtering and full-wave rectification described above, the processed right-LD signal was represented as a 50-ms moving RMS envelope. For each participant, a reference amplitude was defined as the highest right-LD RMS value observed across all retained valid repetitions and all four attachment conditions. The activity-onset threshold was set at 20% of this participant-specific cross-condition maximum RMS amplitude and therefore remained fixed within each participant across attachment conditions and repetitions. EMG-defined activity onset was assigned to the first sample at which the right-LD RMS envelope exceeded this threshold and remained continuously above it for at least 50 ms. This EMG-defined repetition-activity onset was used solely as a reproducible analytical temporal anchor and was not interpreted as the mechanical onset of the repetition. The subsequent nominal 2-second lifting and 2-second lowering intervals prescribed by the metronome were used to define broad cadence-defined analytical windows for sEMG quantification rather than mechanically synchronized phase boundaries. For readability, these windows are referred to as the lifting and lowering analytical intervals; the labels describe the intended portions of the repetition and do not denote precisely identified mechanical phases. Because no common hardware trigger, common clock, or shared timestamp was used, precise frame-by-frame or sample-by-sample temporal correspondence between the kinematic and sEMG signals could not be established. The independently recorded motion-capture data were used to characterize movement execution and active-motion duration, not to establish event-level synchronization with individual sEMG samples. |
| Statistical analysis |
All analyses were performed in R 4.4.1 within RStudio. Primary inference used the available analytical-interval observations remaining after segmentation and data-quality processing. Descriptive values were averaged within each participant, muscle, attachment, and analytical-interval cell, whereas inferential models used repetition-level observations. This modelling approach was used to retain valid repeated observations while accounting for within-participant clustering through random effects rather than treating repetitions as independent participants. Linear mixed-effects models were fitted separately for each muscle. Attachment, phase (operationally representing the cadence-defined lifting versus lowering analytical interval), and their interaction were included as fixed effects. The final primary model for each muscle included a participant-level random intercept and followed the form sEMG amplitude ~ attachment × phase + (1 | participant). More complex participant-level random-effects structures were considered during model checking but were simplified after singular-fit diagnostics; the final structures are reported in Two sensitivity analyses were reported in the supplementary material: models restricted to observations from original repetition positions 1 and 2 and models restricted to participants with complete observations for all four attachment-by-two analytical-interval combinations. The supplementary material also reports retained analytical-interval observations, the distribution of original repetition positions, interquartile-range-based outlier-screening diagnostics, and the final random-effects structure used for the primary models ( Temporal robustness was evaluated using complementary sensitivity analyses that addressed different aspects of uncertainty created by the absence of hardware synchronization. First, velocity-defined pull and return active-motion durations were quantified independently from motion capture ( |
|
|
| Overview |
Fourteen participants contributed to the primary analyses; 13 to 14 participants contributed to the muscle-specific models because of residual missing observations. Missing observations resulted from analytical-window availability, cadence or technique deviations, or signal-quality exclusions rather than participant withdrawal. Retained observations and the distribution of original repetition positions are reported in |
| Between-condition differences |
Between-condition differences were clearest for the posterior deltoid, biceps brachii, and triceps brachii. For the posterior deltoid, there was a condition effect (p = 0.003), whereas the phase main effect and condition-by-phase interaction were not significant. Bonferroni-adjusted comparisons showed greater posterior deltoid sEMG amplitude in the rope condition than in the cambered-bar condition (mean difference = 8.0 %MVIC, 95% CI = 4.1 to 11.9; p = 0.002). For the biceps brachii, condition, phase, and condition-by-phase effects were significant (all p < 0.001). In the lifting analytical interval, the wide V-shaped handle condition showed greater biceps brachii sEMG amplitude than the straight bar (mean difference = 11.0 %MVIC, 95% CI = 6.5 to 15.6; p < 0.001), cambered bar (10.5 %MVIC, 95% CI = 6.0 to 15.0; p < 0.001), and rope (15.7 %MVIC, 95% CI = 11.3 to 20.0; p < 0.001). In the lowering analytical interval, the only significant condition contrast for the biceps brachii was greater sEMG amplitude with the wide V-shaped handle than with the straight bar (7.1 %MVIC, 95% CI = 2.5 to 11.7; p = 0.020). These comparisons describe the complete attachment-specific relative-load conditions; they do not isolate attachment geometry from absolute load. For the triceps brachii, there was a condition effect in the primary model (p = 0.025), whereas the phase main effect and interaction were not significant. The wide V-shaped handle condition showed greater triceps brachii sEMG amplitude than the cambered-bar condition (mean difference = 11.3 %MVIC, 95% CI = 3.4 to 19.2; p = 0.038) and rope condition (10.8 %MVIC, 95% CI = 3.1 to 18.6; p = 0.045). Because the triceps brachii pattern changed in the complete-case sensitivity analysis, these contrasts should be treated as less stable than the posterior deltoid, biceps brachii, and middle trapezius findings. For the latissimus dorsi, neither the condition nor phase main effect was significant, indicating no consistent between-condition difference in latissimus dorsi sEMG amplitude. |
| Analytical-interval effects and condition-by-phase interactions |
Analytical-interval effects were most evident for the biceps brachii and middle trapezius. Biceps brachii sEMG amplitude was greater in the lifting analytical interval than in the lowering analytical interval for the straight bar, wide V-shaped handle, and cambered bar conditions, but not for the rope condition. For the middle trapezius, there was an analytical-interval effect, with greater sEMG amplitude in the lowering analytical interval than in the lifting analytical interval (mean difference = 6.2 %MVIC, 95% CI = 3.3 to 9.1; p < 0.001). This lowering-interval pattern is shown in |
| Sensitivity analyses |
Sensitivity analyses supported different levels of robustness for attachment-related findings and analytical-interval effects. Restricting the analysis to original repetition positions 1 and 2, thereby excluding the few observations in which a later repetition replaced an unusable earlier repetition, preserved the overall inferential pattern. In the complete-case analysis, the posterior deltoid condition effect, the full biceps brachii pattern, and the middle trapezius analytical-interval effect were retained. The latissimus dorsi interaction was attenuated (p = 0.075), and the triceps brachii result shifted from a condition main effect in the primary model to an interaction pattern in the complete-case subset (p = 0.018). Accordingly, latissimus dorsi and triceps brachii should be interpreted as exploratory or less stable findings. The posterior-deltoid and biceps-brachii attachment-related findings showed the strongest robustness across the complementary analyses. The middle-trapezius lowering-versus-lifting analytical-interval difference was also retained in analyses that preserved the interval distinction, but it cannot be evaluated in the boundary-free analysis after removal of the phase term. Independent kinematic characterization quantified velocity-defined active-motion portions that are distinct from the complete nominal metronome intervals; adjustment using participant-by-attachment mean pull/return active-motion duration produced only trivial changes in the principal posterior-deltoid, biceps-brachii, and middle-trapezius contrasts ( |
|
|
The main finding of this randomized crossover study was that sEMG amplitude differed across the four attachment-specific relative-load conditions and the cadence-defined analytical intervals in a muscle-dependent manner. The most consistent attachment-related findings were greater biceps brachii sEMG amplitude in the wide V-shaped handle condition, particularly in the lifting analytical interval, and greater posterior deltoid sEMG amplitude in the rope than cambered-bar condition. The middle trapezius showed greater sEMG amplitude in the lowering analytical interval than in the lifting analytical interval. In contrast, no consistent between-condition difference was found for the latissimus dorsi. Because each condition used 70% of its own 1RM, these findings reflect the combined experimental condition, including both attachment configuration and the absolute load associated with that attachment-specific relative intensity. They should therefore not be interpreted as the isolated effect of attachment geometry. The greater posterior deltoid sEMG amplitude in the rope condition suggests that this condition placed a different acute demand on the posterior shoulder than the cambered-bar condition. The mechanism cannot be assigned to the rope geometry alone because absolute loads also differed among conditions. A plausible contribution is the different distal constraint and coordination demand near the end of the pull. Previous pulling and shoulder-exercise studies support the broader view that exercise configuration can alter posterior-shoulder sEMG amplitude, although those studies differ from the present work in sample characteristics, task constraints, loading, and normalization procedures (Botton et al., The biceps brachii showed the most consistent attachment-related analytical-interval difference. The wide V-shaped handle condition produced the greatest biceps brachii sEMG amplitude, primarily in the lifting analytical interval. This finding is relevant to exercise selection because a wide V-shaped handle is often chosen as a back-training variation, yet one of the clearest sEMG patterns in the present study was greater elbow-flexor amplitude in the intended pulling portion of the repetition. Notably, the wide V-shaped handle condition used a lower mean absolute load than the straight-bar and cambered-bar conditions, so a simple explanation that greater load always produced greater sEMG amplitude does not account for this result. Previous lat pulldown and pull-up studies have also shown that elbow-flexor sEMG amplitude can vary with hand position, exercise configuration, and shoulder-loading strategy (Dickie et al., The absence of a consistent latissimus dorsi difference is important for the practical interpretation of the study. No condition showed a main-effect difference for latissimus dorsi sEMG amplitude, and the condition-by-phase interaction from the primary model weakened in the complete-case sensitivity analysis. These results do not support the common assumption that using a particular pulldown handle necessarily produces different latissimus dorsi sEMG amplitude under attachment-specific relative loading. A more cautious interpretation is that the tested conditions may alter the interval-specific pattern of local latissimus dorsi sEMG amplitude, but these data do not identify a condition that consistently maximizes it. This interpretation is compatible with studies reporting limited latissimus dorsi differentiation across moderate grip-width, hand-position, and front-versus-back pulldown variations (Andersen et al., Triceps brachii sEMG amplitude was higher with the wide V-shaped handle than with the cambered bar and rope in the primary model. Because this pattern was less stable in the complete-case analysis, it should be interpreted as a secondary finding. The pattern may reflect a stabilizing or coordinative role at the elbow under standardized relative loading. In contrast, middle trapezius sEMG amplitude was greater in the lowering analytical interval than in the lifting analytical interval. This pattern may be compatible with greater scapular-control demand during the intended return portion of the repetition and is broadly consistent with observations from other pulling and rowing exercises (Handa et al., From an applied perspective, the four attachment-specific relative-load conditions produced different local sEMG patterns. The wide V-shaped handle condition showed greater elbow-flexor sEMG amplitude in the lifting analytical interval, whereas the rope condition showed greater posterior deltoid sEMG amplitude than the cambered-bar condition. These observations may help practitioners choose among commonly used pulldown setups when relative intensity is prescribed from each attachment's own 1RM. They should not be used to claim that the attachment alone caused the differences. Several limitations define the scope of these conclusions. The sample was modest and limited to resistance-trained young men, reducing generalizability and limiting confidence in small or unstable effects. The findings describe acute sEMG responses and should not be interpreted as direct evidence of long-term hypertrophy, strength, or sport-performance adaptations (Vigotsky et al., The motion-capture and sEMG systems were recorded independently and did not share a hardware trigger, common clock, or common timestamp. Accordingly, the 20% right-LD EMG-defined activity onset should be interpreted as an analytical timing anchor, and the subsequent nominal 2-second lifting and 2-second lowering periods as broad cadence-defined analytical intervals rather than mechanically synchronized movement boundaries. The velocity-defined active-motion durations derived from motion capture represent active portions of the movement and are distinct from the complete nominal metronome intervals; participant-by-attachment mean durations were used only as covariates in the duration-adjusted sensitivity analysis and were not time-registered to individual sEMG samples. Electromechanical delay and temporal differences between electrical activation and observable movement mean that samples close to the assumed transition may be misclassified with respect to the true mechanical reversal. The duration-adjusted models, temporal-window perturbation analysis, and boundary-free nominal 4.0-second analytical-window analysis provided complementary checks of timing sensitivity. These analyses supported the strongest attachment-related posterior-deltoid and biceps-brachii findings across complementary timing assumptions, although some biceps-brachii contrasts were attenuated when the analytical windows were shifted later. The middle-trapezius lowering-versus-lifting analytical-interval difference was retained in analyses that preserved the interval distinction but cannot be evaluated in the boundary-free analysis after removal of the phase term. Therefore, these sensitivity analyses do not validate the true mechanical boundary; rather, they indicate that the principal attachment-related conclusions are not wholly dependent on one millisecond-precise nominal transition. For the same reason, more temporally specific analyses, such as the final 0.5 seconds of the intended pulling portion, were not performed because they would have required more precise event-level temporal alignment than was available. Surface electromyography represents electrical signals recorded at standardized recording sites, not whole-muscle force. This limitation is especially relevant for broad muscles such as the latissimus dorsi and trapezius, where regional heterogeneity, muscle thickness under the electrodes, subcutaneous tissue, crosstalk, electrode orientation, and electrode location relative to innervation zones can influence absolute amplitude values (Barbero et al., |
|
|
In resistance-trained men, sEMG amplitude differed across front lat pulldown conditions performed at 70% of attachment-specific 1RM and across cadence-defined lifting and lowering analytical intervals. The wide V-shaped handle condition showed the clearest biceps brachii difference, the rope condition showed greater posterior deltoid sEMG amplitude than the cambered-bar condition, and the middle trapezius showed greater sEMG amplitude in the lowering analytical interval than in the lifting analytical interval. No consistent between-condition difference was found for latissimus dorsi sEMG amplitude, and latissimus dorsi- and triceps brachii-related secondary findings were less stable across sensitivity analyses. Because the motion-capture and sEMG systems were not hardware synchronized, the lifting/lowering interval findings should not be interpreted as mechanically validated phase boundaries. Because absolute loads differed among the attachment-specific relative-load conditions, these results should not be attributed solely to attachment geometry. They also should not be interpreted as evidence of superior long-term strength or hypertrophic adaptations. |
| ACKNOWLEDGEMENTS |
The authors thank all participants for their time and effort and acknowledge the assistance of the research staff involved in data collection and processing. This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. The authors declare no conflict of interest. Deidentified data underlying the findings are available from the corresponding author on reasonable request. All experimental procedures were conducted in compliance with the relevant legal and ethical standards of the country where the study was carried out. The authors declare that no Generative AI or AI-assisted technologies were used in the writing of this manuscript. |
| AUTHOR BIOGRAPHY |
|
| REFERENCES |
|