| Research article - (2026)25, 960 - 971 DOI: https://doi.org/10.52082/jssm.2026.960 |
| Morphological and Functional Adaptations of the Triceps Surae Complex to Eccentric Quasi-Isometric versus Eccentric Resistance Exercise in Healthy, Regularly Trained Adults: A Randomised Controlled Trial |
Luka Križaj1, Žiga Kozinc1,2, , Nejc Šarabon1,2 |
| Key words: Ankle plantar flexors, eccentric quasi-isometric contraction, eccentric contraction, muscle and tendon morphology, strength |
| Key Points |
|
|
|
The trial was prospectively registered in the International Standard Randomised Controlled Trial Number (ISRCTN) registry (ISRCTN35199955). The study was conducted at the Faculty of Health Sciences, University of Primorska, Izola, Slovenia, between November 2025 and January 2026. |
| Participants |
For the study, 48 healthy adults (26 male and 22 female) were recruited and equally divided into three groups. The sample size was calculated using the G*Power tool (version 3.1.9.7) for the interaction in a mixed analysis of variance, assuming an effect size f = 0.25, corresponding to a partial η2 = 0.06, a standard error α = 0.05, and statistical power 0.80 (Morrissey et al., |
| Study design |
This study was a three-arm parallel-group randomised controlled trial with a 1:1:1 allocation ratio, using a pre-post repeated-measures design to evaluate the effects of a six-week exercise intervention. Within each sex stratum, a random allocation sequence was generated using the RAND function in Microsoft Excel (Microsoft Corp., Redmond, WA, USA) with a 1:1:1 allocation ratio into one of the three groups (EQI, ECC or control). To avoid data variability, differences in foot dominance between subjects (whether the dominant side is the take-off or the kicking side) and in order to obtain more comparable results, in all participants, only the right limb was assessed. |
| Measurement protocol |
The measurement protocol consisted of separate morphological, ankle mobility and strength measurements. A detailed outline of all measurement procedures is available in Supplementary file 1. The whole protocol began with the ultrasound measurements executed using an ultrasound device (Resona 7, Mindray, China) and was carried out using the L11-3U ultrasound probe. During ultrasound measurements, all participants were lying in a prone position with their ankle over the edge of the therapeutic table (Supplementary file 1 - Figure S1A). The ultrasound protocol comprised three Achilles tendon thickness (Supplementary file 1- Figure S1B) and stiffness measurements (Supplementary file 1 - Figure S1C) (Mifsud et al., Before the strength measurements, which focused on measuring concentric, ECC and isometric maximal voluntary contraction and three EQI actions, each participant executed a standardised warm-up protocol. The protocol consisted of three minutes of light jogging (on a treadmill) and four minutes of stepping onto a 10-centimetre-high platform (alternating with each leg for 60 seconds, increasing the stepping velocity in the second series) followed by dynamic stretching exercises and ten repetitions of active strengthening exercises (jumping jacks, squats, push-ups, and heel raises with both feet without additional weight). After the participant finished with a warm-up, they moved to the isokinetic dynamometer (HumacNorm, Computer Sports Medicine Inc., Stoughton, MA, USA), where we initially adjusted the settings of the seat and footrest part of the dynamometer (i.e., the backrest, knee and lumbar support, plantar support, etc.) and straps, following our previous studies (Supplementary file 1 - Figure S3) (Križaj et al., |
| Intervention protocol |
After the baseline measurement, participants in the control group had to continue their normal physical activity, but without any direct exercise that would affect changes in the ankle plantar flexors (i.e., exercises for direct strengthening or stretching of the ankle plantar flexors; plyometric exercise, etc.) until the execution of the post-measurement. Meanwhile, the EQI and ECC group participants executed a six-week exercise protocol that consisted of 12 exercise sessions, which had to be performed twice a week, with at least two days of rest between sessions. The exercise protocol began five days after the baseline measurement, while the post-measurement was then performed three days after the last exercise session. The exercise session began with the same warm-up (Supplementary file 3 - Figure S4) as in the case of the baseline measurement. Then, in both protocols, heel raise repetitions had to be performed on a Smith machine. The repetitions began in a standing position on a higher platform (or stepper) with an Olympic barbell (and additional weights) placed across the trapezius muscle. The subjects had the distal third of their feet (including the footpads) in contact with the higher platform. In both protocols, participants executed bilateral heel raise to the highest position with their knees extended (Supplementary file 3 - Figure S5A). In the EQI group, participants unilaterally attempted to hold the reached position isometrically (Supplementary file 3 - Figure S5B), while the ankle gradually moved into increasingly greater dorsal flexion that the subjects resisted. The end of the contraction was determined when the ankle plantar flexors were unable to overcome the load or the ankle reached its final RoM (the participants touched the ground with their heel or began to overcome the load with the help of the other, passive leg) (Supplementary file 3 - Figure S5C). Meanwhile, the participants in the ECC group executed controlled three-second unilateral heel drop in the direction of ankle dorsal flexion, which was followed by a repeat of the repetition until the end of the set. All exercise sessions were executed on the right leg only. Both interventions were matched in load and time under tension. A load equal to 1 RM was set for each participant. The performance value was measured for all individuals, regardless of group, in accordance with an adapted version presented in the NSCA’s “Essentials of Strength and Conditioning, 4th Edition” (Haff and Triplett, The load corresponded to the individual’s 1 RM and was re-assessed following the same procedure before sessions 1, 5, and 9; therefore, Load 1 was used in sessions 1-4, Load 2 in sessions 5-8, and Load 3 in sessions 9-12. Time under tension progressively increased from 90 s in sessions 1-2 to 135 s in sessions 3-6 and 180 s in sessions 7-12. In the EQI group, participants repeated EQI actions with two-minute breaks until the prescribed time under tension was achieved. In the ECC group, the corresponding volume was 2 × 15 repetitions in sessions 1-2, 3 × 15 repetitions in sessions 3-6, and 4 × 15 repetitions in sessions 7-12 (See Supplementary File 3 - Table S2 for details). The suitability of implementing the intervention protocol on the Smith machine, and protocols’ load and RoM were predetermined based on the previously conducted pilot study with 8 participants (4 men, 4 women) (See Supplementary file 2 for details). The results of the pilot study (Supplementary file 2) showed that the dynamics of EQI actions on the Smith machine, without RoM restriction and at a load equal to 1 RM, are most comparable to those achieved on an isokinetic dynamometer. All exercise sessions were supervised by the researchers, who corrected the execution of the movement task if needed, videorecorded the repetitions and measured the time under tension and resting time (especially in the EQI group). The repetitions were recorded using a high-resolution camera positioned to provide a clear view of the movement in the sagittal plane. Reflective markers were placed on the relevant anatomical landmarks (i.e., slightly distal to the medial malleolus, on the medial tibial condyle and on the head of the first metatarsal bone) by a researcher who was present during the exercise session. The EQI repetitions were analysed in the Kinovea tool. A semi-automatic analysis function was used to identify the marker positions and determine the starting and final ankle angles in the sagittal plane and the time under tension of a single contraction. Based on these values, the angular velocity at which the participant performed the contraction was calculated. Although the semi-automatic function was used for the analysis, each video recording was carefully reviewed by the researcher. Whenever any deviation or error in marker detection or tracking was identified, the marker position was manually corrected before the angular velocity was calculated, thus ensuring the accuracy of the analysed data. At the beginning of each exercise session, the participants had to report the level of delayed muscle soreness they felt in the triceps surae region, while after completing the exercise protocol, they had to report the effort score for that exercise session. Both variables were rated on a 10-point scale, where a higher value meant a higher level of pain or effort that the person felt. |
| Data processing |
Ultrasound measurements were averaged across repetitions, using the mean values for tendon thickness and stiffness, and gastrocnemius muscle fascicle length, pennation angle and thickness. All signals obtained using an isokinetic dynamometer (time, ankle position, torque and angular velocity), were sampled at 100 Hz frequency and analysed without prior filtering (Oranchuk et al., |
| Statistical analysis |
The per-protocol population comprised participants who completed post-intervention testing and, in the intervention groups, attended ≥ 10 of 12 supervised sessions (≥ 83%). The per-protocol approach was prioritized to assess physiological adaptations following sufficient exposure to the prescribed exercise intervention. As a sensitivity analysis, all randomized participants were included in linear mixed-effects models with group, time, and group × time as fixed effects and participant as a random effect, using all available observations without imputation of missing data. No interim analyses were performed, no stopping guidelines were pre-specified, and no changes to the pre-specified outcomes were made after trial commencement. We presented the data as means ± standard deviation. We checked the normality of the data distribution using the Shapiro-Wilk test and visual inspection of histograms and Q - Q plots. The threshold for statistical significance was set at p < 0.05. We checked the baseline differences between groups with a unifactorial analysis of variance (ANOVA). Mixed-model ANOVA was used to check the differences according to group (EQI, ECC and control group; between-subjects factor), time (baseline and post-measurements; within-subjects factor), and the interaction between group and time. We calculated the effect size as partial η2, which was interpreted as trivial (< 0.01), small (0.01-0.06), medium (0.06-0.14), or large (> 0.14) (Richardson, |
|
|
Of the 48 randomised participants, 46 completed the study and were included in the per-protocol analysis (EQI, n = 15; ECC, n = 15; control, n = 16). Two participants withdrew during the intervention period; one of them dropped out of the study early due to a lack of time, while the other did so because of an injury unrelated to the ankle or to exercising on the Smith machine. No intervention-related adverse events were reported. Baseline demographic and outcome measures did not differ between groups (all p ≥ 0.166). Participant flow is shown in |
| Intervention characteristics |
The EQI group required approximately two repetitions to achieve 90 s of total time under tension, two to three repetitions to achieve 135 s, and three to four repetitions to achieve 180 s. Mean angular velocity during Smith-machine EQI exercise ranged from -0.448 to -0.608°·s–1. |
| Muscle and tendon adaptations |
Significant group × time interactions were observed for Achilles tendon thickness and most gastrocnemius architecture outcomes (p ≤ 0.001; partial η2 = 0.30-0.56). Achilles tendon thickness, medial and lateral gastrocnemius fascicle length, muscle thickness, and lateral gastrocnemius pennation angle increased in both intervention groups (all p < 0.001; partial η2 = 0.53-0.79). Changes did not differ between EQI and ECC training (p = 0.227-0.965) ( Achilles tendon stiffness and medial gastrocnemius pennation angle did not show significant group × time interactions (p = 0.157-0.767). Although a small increase in lateral gastrocnemius fascicle length was also observed in the control group (p = 0.048; partial η2 = 0.24), the corresponding effects were larger in the EQI and ECC groups (both p < 0.001; partial η2 = 0.71-0.76) ( |
| Range of motion and strength |
Open-chain ankle dorsiflexion increased in the EQI and ECC groups (p = 0.014-0.019; partial η2 = 0.33-0.36), but the group × time interaction was not significant (p = 0.148). Closed-chain dorsiflexion showed a significant group × time interaction (p = 0.029; partial η2 = 0.15) and increased in all groups (p = 0.003-0.045; partial η2 = 0.24-0.61). Changes in either dorsiflexion outcome did not differ between EQI and ECC training (p = 0.648-0.885) ( Significant group × time interactions were observed for concentric, eccentric, and isometric plantar-flexor strength (all p < 0.001; partial η2 = 0.30–0.43). All three strength outcomes increased in both intervention groups (p ≤ 0.001; partial η2 = 0.58-0.77), whereas no significant changes were observed in the control group (p = 0.193-0.954). Improvements did not differ between EQI and ECC training (p = 0.561-0.976) ( |
| Eccentric quasi-isometric performance |
There were significant main effects of time for EQI time under tension and total torque impulse (p = 0.002-0.003; partial η2 = 0.19-0.21), but no significant group × time interactions (p = 0.170-0.229). Within-group analyses showed increases after ECC training (p = 0.012-0.020; partial η2 = 0.33-0.37), but not after EQI training or in the control group (p = 0.084-0.382). Changes did not differ between the EQI and ECC groups (p = 0.958-0.961). EQI angular velocity remained unchanged, with no significant time, group, or interaction effects (p = 0.246-0.805) ( |
| Pain and perceived effort |
Pain scores were significantly lower after executing EQI than ECC training (1.29 vs 1.69 points; p = 0.004; partial η2 for the group effect = 0.15), although pain remained low in both groups. Perceived effort was moderate to high and did not differ between interventions (6.11-6.68 points; p = 0.229). A small effect of time was observed for perceived effort (p = 0.012; partial η2 = 0.09), without a significant group × time interaction (p = 0.737) ( |
|
|
The results showed that both interventions induced increases in Achilles tendon thickness, gastrocnemius fascicle length (medial and lateral head), gastrocnemius thickness (medial and lateral head), lateral gastrocnemius pennation angle, dorsiflexion RoM, and plantarflexion strength compared to the control group, while the statistically significant differences between protocols were not detected. Meanwhile, the improvements in EQI time under tension and total torque impulse were observed only following ECC training according to within-group analysis; however, between-group differences were not statistically significant. Previous studies (Lazarczuk et al., There could be several reasons for conflicting findings in this case. In the previous study, thickness was measured at two points - one and three cm above the tendon insertion on the heel (Sanz-López et al., An increase in the fascicle length and pennation angle of the gastrocnemius is directly related to an increase in strength (Narici et al., Meanwhile, Henderson et al. ( The increase in ankle dorsiflexion RoM as a result of EQI or ECC training is consistent with the findings of previous study (Rout et al., The results of the study showed that both protocols, EQI and ECC, increased concentric, ECC and isometric strength of the ankle plantar flexors, without any detected differences between protocols. Although EQI exercise is performed at a lower angular velocity than ECC-only contraction, both protocols are based on ECC contraction. Previous evidence suggests that strength increase after ECC exercise is velocity-independent when overall time under tension and load magnitude are matched between the protocols (Marzilger et al., Regardless of the fact that the results showed a statistically significant increase in the time under tension and total torque impulse of EQI action only in the ECC group, but not in the EQI group, the between-group analysis showed that there were no statistically significant differences between the protocols. These results were most likely due to (statistically insignificant) differences in the baseline, where, on average, the participants in the EQI group achieved both higher times under tension and higher total torque impulse values. In addition, minor positive changes in the ECC group or insignificant changes in the aforementioned parameters in the case of the EQI group, with a simultaneous increase in isometric strength (which we used to calculate the load that the subjects overcame), are already associated with progress in itself, as the participant overcame the higher load in the same (or longer) time. It should be noted that there were most likely no noticeable changes in the total torque impulse, as the value was not determined solely by trapezoidal integration of the area under the torque curve and time, but as the calculated trapezoidal integration divided by the isometric strength, which was higher in the post-measurement case than in the baseline measurement case. Similarly, we can also understand why there was no reduction in the angular velocity of EQI action in any of the groups. The study showed that the protocols differ statistically significantly in terms of the level of pain caused by EQI or ECC contractions. These results are most likely due to the higher number of repetitions and higher movement velocities to which the ECC group participants were exposed (Chapman et al., Based on the present findings, several directions for future research can be identified. First, extending the duration of the intervention would help determine whether EQI and ECC differ in their long-term effects. Second, incorporating multiple intermediate and follow-up assessment time points would allow a more detailed characterisation of the time course and retention of adaptations. Third, future studies should include additional functional performance outcomes, such as squat jump and countermovement jump performance. Finally, the applicability of EQI training should be examined in pathological populations, particularly individuals with Achilles tendinopathy. |
| Limitations |
Several limitations of this study should be acknowledged. First, laboratory-based outcomes were assessed only at baseline and post-intervention, limiting insight into the temporal progression of adaptations. Second, the findings cannot be readily generalised to the broader population, as the sample consisted exclusively of young, healthy, and physically active individuals. Third, the results cannot be extrapolated to populations with Achilles tendon pathologies. Fourth, due to the nature of the exercise interventions, participant and therapist blinding was not possible, which may have introduced performance bias despite standardised supervision and testing procedures. In addition, because analyses were conducted per-protocol and excluded participants who withdrew, the estimated effects may be sensitive to attrition-related bias. Finally, pain and effort outcomes were derived from subjective self-reports and may have been influenced by individual pain tolerance and prior training experience. |
|
|
This study provides evidence that EQI and traditional ECC training can induce positive adaptations in the triceps surae muscle-tendon unit when load and time under tension are matched, while statistically significant differences were not detected. These findings are relevant for sports medicine and rehabilitation because EQI exercise may offer a controlled high-load stimulus with lower perceived muscle soreness than ECC exercise, while producing similar improvements in plantar flexor strength, ankle dorsiflexion, and muscle-tendon morphology. The results therefore support EQI exercise as a potentially useful alternative to conventional ECC loading in contexts where high mechanical tension is desired but excessive soreness or repeated faster eccentric actions may be undesirable. Future studies should determine whether these findings extend to athletes, older adults, and patients with Achilles tendon disorders, and whether longer interventions reveal protocol-specific differences in tendon stiffness, functional performance, or symptom responses. |
| ACKNOWLEDGEMENTS |
Datasets generated during the current study are not publicly available but are available from the corresponding author upon reasonable request. The authors declare that they have no conflict of interest. All experimental procedures were conducted in compliance with the relevant legal and ethical standards of the country where the study was carried out. The authors declare that no Generative AI or AI-assisted technologies were used in the writing of this manuscript. The authors declare that financial support was received by the Slovenian Research and Innovation Agency (ARIS) through the post-doctoral project EQI-TRAIN: Establishing scientific foundations for eccentric quasiisometric resistance training (Z5-50181 (B)) and research program KINSPO - Kinesiology for the effectiveness and prevention of musculoskeletal injuries in sports (P5-0443). |
| AUTHOR BIOGRAPHY |
|
| REFERENCES |
|