Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
ISSN: 1303 - 2968   
Ios-APP Journal of Sports Science and Medicine
Views
9148
Download
1268
from September 2014
 
©Journal of Sports Science and Medicine (2003) 02, 151 - 157

Research article
Can Aerobic and Anaerobic Power be Measured in a 60-Second Maximal Test?
Daniel G. Carey1, , Mark T. Richardson2
Author Information
1 University of St. Thomas, St. Paul, Minnesota, USA
2 University of Alabama, Tuscaloosa, Alabama, USA

Daniel G. Carey
✉ Mail #5003, 2115 Summit Avenue, University of St. Thomas, St. Paul, Minnesota, 55105, USA.
Email: dgcarey@stthomas.edu
Publish Date
Received: 29-07-2003
Accepted: 12-10-2003
Published (online): 01-12-2003
 
 
ABSTRACT

The primary objective of this study was to assess the efficacy of measuring both aerobic and anaerobic power in a 60-second, maximal effort test. It was hypothesized that oxygen consumption increases rapidly during maximal effort and maximal oxygen consumption (VO2 max) may be reached in one minute. Fifteen United States Cycling Federation competitive cyclists performed the following tests: 1) practice 60-second maximal exertion test; 2) standard incremental workload VO2 max test; 3) Wingate anaerobic power test (WAT); 4) VO2 measured during 60-second maximal exertion test (60-SEC); and 5) VO2 measured during 75-second maximal exertion test (75-SEC). All tests were performed on an electrically-braked cycle ergometer. Hydrostatic weighing was performed to determine percent body fat. Peak oxygen consumption values for the 60-SEC (53.4 ml·kg-1·min-1, 92% VO2 max), and 75-SEC (52.6 ml·kg-1·min-1, 91% VO2 max) tests were significantly lower than VO2 max (58.1 ml·kg-1·min-1). During the 75-SEC test, there was no significant difference in percentage VO2max from 30 seconds to 75 seconds, demonstrating a plateau effect. There were no significant differences in peak power or relative peak power between the Wingate, 60-SEC, and 75 SEC tests while, as expected, mean power, relative mean power, and fatigue index were significantly different between these tests. Power measures were highly correlated among all three tests. It was concluded that VO2 max was not attained during either the 60-SEC nor 75-SEC tests. Furthermore, high correlations in power output for WAT, 60-SEC, and 75-SEC precludes the necessity for anaerobic tests longer than the 30-second WAT.

Key words: Maximal oxygen consumption, Wingate


           Key Points
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.