Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
ISSN: 1303 - 2968   
Ios-APP Journal of Sports Science and Medicine
Views
10242
Download
1349
from September 2014
 
©Journal of Sports Science and Medicine (2010) 09, 176 - 182

Research article
Heart Rate Variability Before and After Cycle Exercise in Relation to Different Body Positions
Otto F. Barak1, , Djordje G. Jakovljevic2, Jelena Z. Popadic Gacesa1, Zoran B. Ovcin3, David A. Brodie4, Nikola G. Grujic1
Author Information
1 Medical School, University of Novi Sad, Novi Sad, Serbia
2 Newcastle Magnetic Resonance Centre, Muscle Performance and Exercise Training Laboratory, Institute for Ageing and Health, Newcastle University, UK
3 University of Novi Sad, Novi Sad
4 Buckinghamshire New University, UK

Otto F. Barak
✉ Department of Physiology, Medical School, University of Novi Sad, 3, Hajduk Veljko street, 21000 Novi Sad, Serbia
Email: ottompotom@uns.ac.rs
Publish Date
Received: 01-12-2009
Accepted: 08-01-2010
Published (online): 01-06-2010
 
 
ABSTRACT

The purpose of this study was to assess the effect of three different body positions on HRV measures following short-term submaximal exercise. Thirty young healthy males performed submaximal cycling for five minutes on three different occasions. Measures of HRV were obtained from 5-min R to R wave intervals before the exercise (baseline) and during the last five minutes of a 15 min recovery (post-exercise) in three different body positions (seated, supine, supine with elevated legs). Measures of the mean RR normal-to-normal intervals (RRNN), the standard deviation of normal-to-normal intervals (SDNN), the root mean square of successive differences (RMSSD) and the low-frequency (LF) and the high-frequency (HF) spectral power were analyzed. Post-exercise RRNN, RMSSD were significantly higher in the two supine positions (p < 0. 01) compared with seated body position. Post-exercise ln LF was significantly lower in the supine position with elevated legs than in the seated body position (p < 0.05). No significant difference was found among the three different body positions for post-exercise ln HF (p > 0.05). Post-exercise time domain measures of HRV (RRNN, SDNN, RMSSD) were significantly lower compared with baseline values (p < 0.01) regardless body position. Post-exercise ln LF and ln HF in all three positions remained significantly reduced during recovery compared to baseline values (p < 0.01). The present study suggests that 15 minutes following short-term submaximal exercise most of the time and frequency domain HRV measures have not returned to pre-exercise values. Modifications in autonomic cardiac regulation induced by body posture present at rest remained after exercise, but the post-exercise differences among the three positions did not resemble the ones established at rest.

Key words: Heart rate variability, recovery, exercise


           Key Points
  • Whether different body positions may enhance post-exercise recovery of autonomic regulation remains unclear.
  • The absence of restoration of HRV measures after 15 minutes of recovery favor the existence of modifying effects of exercise on mechanisms underlying heart regulation.
  • On the basis of discrepancies in HRV measures in different body positions pre- and post-exercise we argue that the pace of recovery of cardiac autonomic regulation is dependent on body posture.
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.