Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
ISSN: 1303 - 2968   
Ios-APP Journal of Sports Science and Medicine
Views
9921
Download
1338
from September 2014
 
©Journal of Sports Science and Medicine (2011) 10, 616 - 623

Research article
Validity of the Modified Conconi Test for Determining Ventilatory Threshold During On-Water Rowing
Jorge Villamil Cabo1, , Pablo Martinez-Camblor2, Miguel del Valle3
Author Information
1 Sport Medicine School, University of Oviedo, Spain
2 Biosanitary Research Office of Asturias,
3 Sport Medicine School, University of Oviedo, Spain

Jorge Villamil Cabo
✉ Sport Medicine School, University of Oviedo, Spain
Email: jorgevc@educastur.princast.es
Publish Date
Received: 03-03-2011
Accepted: 02-08-2011
Published (online): 01-12-2011
 
 
ABSTRACT

The objectives of this study were to design a field test based on the Conconi protocol to determine the ventilatory threshold of rowers and to test its reliability and validity. A group of sixteen oarsmen completed a modified Conconi test for on-water rowing. The reliability of the detection of the heart rate threshold was evaluated using heart rate breaking point in the Conconi test and retest. Heart rate threshold was detected in 88.8% of cases in the test-retest. The validity of the modified Conconi test was evaluated by comparing the heart rate threshold data acquired with that obtained in a ventilatory threshold test (VT2). No significant differences were found for the values of different intensity parameters i.e. heart rate (HR), oxygen consumption (VO2), stroke rate (SR) and speed (S) between the heart rate threshold and the ventilatory threshold, (170.9 ± 6.8 vs. 169.3 ± 6.4 beats·min-1; 42.0 ± 8.6 vs. 43.5 ± 8.3 ml·kg-1·min-1; 25.8 ± 3.3 vs. 27.0 ± 3.2 strokes·min-1 and 14.4 ± 0.8 vs. 14.6 ± 0.8 km·h-1). The differences in averages obtained in the Conconi test-retest were small with a low standard error of the mean. The reliability data between the Conconi test-retest showed low coefficients of variations (CV) and high intraclass correlation coefficients (ICC). The total errors for the Conconi test-retest are low for the measured variables (1.31 HR, 0.87 VO2, 0.65 SR, and 0.1 S). The Bland- Altman’s method for analysis validity showed a strong concordance according to the analyzed variables. We conclude that the modified Conconi test for on-water rowing is a valid and reliable method for the determination of the second ventilatory threshold (VT2).

Key words: Field test, anaerobic threshold heart rate, ventilatory threshold


           Key Points
  • The Modified Conconi test for on-water rowing is a simple and non-invasive method for the determination of anaerobic threshold for on-water rowing.
  • The modified Conconi protocol for rowing was also shown to be a valid protocol for the calculation of the second ventilatory threshold using the ventilatory method.
  • The Bland-Altman analysis suggests an adequate concordance for the modified Conconi test with the ventilatory method for the measurement of the ventilatory threshold.
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.