Accuracy and Reliability of a New Tennis Ball Machine
Cyril Brechbuhl1,2, , Grégoire Millet2, Laurent Schmitt2,3
Author Information
1 French Tennis Federation, Stade Roland-Garros, 2 avenue Gordon Bennett, Paris, France
2 Institute of Sport Sciences (ISSUL), Department of Physiology, Faculty of Biology and Medicine, University of Lausanne, Switzerland
3 National Centre of Nordic-Ski, Research and Performance, Premanon, France

Cyril Brechbuhl
✉ French Tennis Federation, Stade Roland-Garros, 2 avenue Gordon Bennett, Paris, France
Email: cyril.brechbuhl@unil.ch
Publish Date
Received: 06-10-2015
Accepted: 23-02-2016
Published (online): 23-05-2016
 
 
ABSTRACT

The aim was to evaluate the reliability of a newly-developed ball machine named 'Hightof', on the field and to assess its accuracy. The experiment was conducted in the collaboration of the 'Hawk-Eye' technology. The accuracy and reliability of this ball machine were assessed during an incremental test, with 1 min of exercise and 30 sec of recovery, where the frequency of the balls increased from 10 to 30 balls·min-1. The initial frequency was 10 and increased by 2 until 22, then by 1 until 30 balls·min-1. The reference points for the impact were 8.39m from the net and 2.70m from lateral line for the right side and 2.83m for the left side. The precision of the machine was similar on the right and left sides (0.63 ± 0.39 vs 0.63 ± 0.34 m). The distances to the reference point were 0.52 ± 0.42, 0.26 ± 0.19, 0.52 ± 0.37, 0.28 ± 0.19 m for the Y-right, X-right, Y-left and X-left impacts. The precision was constant and did not increase with the intensity. (e.g ball frequency). The ball velocity was 86.3 ± 1.5 and 86.5 ± 1.3 km·h-1 for the right and the left side, respectively. The coefficient of variation for the velocity ranged between 1 and 2% in all stages (ball velocity ranging from 10 to 30 balls·min-1). Conclusion: both the accuracy and the reliability of this new ball machine appear satisfying enough for field testing and training.

Key words: Technology, tennis, testing, training, ball-machine


           Key Points
  • The reliability and accuracy of a new ball machine named 'Hightof' were assessed.
  • The impact point was reproducible and similar on the right and left sides (±0.63 m).
  • The precision was constant and did not increase with the intensity (e.g ball frequency).
  • The coefficient of variation of the ball velocity ranged between 1 and 2% in all stages (ball velocity ranging from 10 to 30 balls·min-1).
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.